SWP-LCD-NLT Natural Gas Flow Totalizer

$1,000.00

Category:

Product Description:

The SWP-LCD series PID self-tuning controllers are suitable for systems requiring high-precision measurement and control.
The SWP-LCD series integrates digital and analog instrumentation, enabling digital display and control of measurement signals such as temperature, pressure, level, and speed, making the readings clearer and more intuitive.


1. Main Features

  1. Equipped with one PID control output and one transmitter output, suitable for various measurement and control scenarios.

  2. Hand/Auto mode switching without disturbance; parameters can be modified in manual or automatic mode.

  3. Multiple control output methods available: PWM output, SCR trigger output, solid-state relay output, and voltage/current output.


2. Special Technical Specifications

Control Output Methods:

  • PWM output, SCR trigger output, solid-state relay output, voltage/current output

Setting/Display Accuracy:

  • ±0.5% FS + 1 digit max. The set value matches the display value with no relative error

Proportional Range:

  • 0.0%–100.0% (0.1% increments)

Integral (Reset) Time:

  • 0–9,999 s (1 s increments)

Derivative (Rate) Time:

  • 0–9,999 s (1 s increments)

Control Cycle:

  • 1–250 s (1 s increments)

Sampling Period:

  • 0.5 s


3. Instrument Dimensions and Wiring Diagrams

SWP-LCD-NP Series (Horizontal)

  • Instrument Dimensions: 160 × 80 × 140 mm

  • Cutout Dimensions: 152 × 76 mm

  • Weight: 400 g

SWP-LCD-NP Series (Vertical)

  • Instrument Dimensions: 80 × 160 × 140 mm

  • Cutout Dimensions: 76 × 152 mm

  • Weight: 400 g


4. SWP-LCD Series PID Self-Tuning Controller Model Code Table

Model Example:

  • SWP-LCD-N □□□□-□□□-□□-□□-□-□ — New generation PID self-tuning controller

Feature Code Description
Display Type D/S Horizontal / Vertical
Dimensions 8 160×80 mm (Horizontal), 80×160 mm (Vertical)
Control Function 05 PID self-tuning control
Communication 0/2/4/8/9 None, RS-232, RS-422, RS-485, Special
Control Output See “Control Output Methods”
Transmitter Output See “Transmitter Output Methods”
Input Type □□ See “Input Types”
Alarm Type N/H/L None, Upper Limit, Lower Limit
Second Alarm See “Alarm Types”
Power Supply Output P DC24V Feed Output
Power Supply W/T DC24V, AC90–265V (Switching), AC220V (Linear)

Input Types & Measurement Ranges:

Code Type Range
01 B 400–1800°C
02 S 0–1600°C
03 K 0–1300°C
04 E 0–1000°C
05 T -200–400°C
06 J 0–1200°C
07 WRe 0–2300°C
08 Pt100 -200–650°C
09 Pt100.1 -99.9–199.9°C

Transmitter Output Methods:

Code Output Type
0 None
1 Relay
2 4–20 mA
3 0–10 mA
4 1–5 V
5 0–5 V

Alarm Output Types:

Code Output
N None
H Upper Limit
L Lower Limit
G Deviation Within
A Deviation Outside
D LBA Alarm

Control Output Methods:

Code Type
0 None
1 Relay
2 4–20 mA
3 0–10 mA
4 1–5 V
5 0–5 V
6 SCR Trigger
7 SSR
8 Special
9 SOT

Model Examples:

  1. SWP-LCD-NP805-21-09-HL-P-W-S

    • RS-232 communication, relay output, Pt100.1 input, upper limit alarm (primary), lower limit alarm (secondary), DC24V feed output, DC24V power supply, vertical display.

  2. SWP-LCD-NP805-81-08-LH-P-T

    • RS-485 communication, relay output, Pt100 input, lower limit alarm (primary), upper limit alarm (secondary), DC24V feed output, AC90–265V switching power supply.

Reviews

There are no reviews yet.

Be the first to review “SWP-LCD-NLT Natural Gas Flow Totalizer”