Product Description:

Condenser
To prevent high-temperature media from damaging the differential pressure transmitter, a condenser should be installed on the pressure transmitting tube between the throttling device and the differential pressure transmitter to protect the transmitter.

(1) Models and Applicable Range

Model Applicable Range
FL-6.4 Pressure ≤6.4 MPa
FL-10 Pressure ≤10.0 MPa
FL-20 Pressure ≤20.0 MPa
FL-30 Pressure ≤30.0 MPa

(2) Structural Form: (As shown in the right figure)


Isolator
To prevent corrosive media from damaging the differential pressure transmitter, an isolator should be installed on the pressure transmitting tube between the throttling device and the differential pressure transmitter to protect the transmitter.

  • When the medium density is greater than the isolating liquid density, use FG-A type.

  • When the medium density is less than the isolating liquid density, use FG-B type.

(1) Models and Applicable Range

Model Applicable Range
FG-6.4A Pressure ≤6.4 MPa
FG-10A Pressure ≤10.0 MPa
FL-6.4B Pressure ≤6.4 MPa
FL-10B Pressure ≤10.0 MPa

(2) Structural Form: (As shown in the right figure)


Gas Collector and Settler

  • When the measured medium is liquid, to prevent gas from being present in the pressure transmitting tube and affecting measurement, a gas collector is generally installed at the highest point of the pressure transmitting tube to periodically discharge gas from the tube and improve measurement accuracy.

  • When the measured medium is gas, to prevent liquid from being present in the pressure transmitting tube and affecting measurement, a settler is generally installed at the lowest point of the pressure transmitting tube to periodically discharge liquid from the tube and improve measurement accuracy.

(1) Models and Applicable Range

Model Applicable Range
FJ-6.4 Pressure ≤6.4 MPa
FJ-10 Pressure ≤10.0 MPa
FC-6.4 Pressure ≤6.4 MPa
FC-10 Pressure ≤10.0 MPa

(2) Structural Form: (As shown in the right figure)


Balancer

  • A single-layer balancer is used when measuring the liquid level of open containers or low-pressure vessels.

  • A double-layer balancer is used when measuring the water level in a boiler drum.

(1) Models and Applicable Range

Model Name Applicable Range
FP6.4A Single-layer Balancer Pressure ≤6.4 MPa
FP-20A Single-layer Balancer Pressure ≤20.0 MPa
FP-32B Single-layer Balancer Pressure ≤32.0 MPa
FP-6.4B Double-layer Balancer Pressure ≤6.4 MPa
FP-25B Double-layer Balancer Pressure ≤25.0 MPa